HP
|
KW
|
I |
FUS
|
PROT
|
I
|
FUS
|
PROT
|
I
|
FUS
|
PRO
|
|
|
115 |
115
|
115 |
220 |
220 |
220 |
440 |
440
|
440 |
1/6 |
0.12
|
4.4
|
8
|
16
|
|
|
|
|
|
|
1/4 |
0.19 |
5.8 |
10
|
16
|
|
|
|
|
|
|
1/3 |
0.25 |
7.2 |
16
|
20
|
|
|
|
|
|
|
1/2 |
0.37 |
9.8 |
20
|
25
|
2.2
|
4
|
6
|
1.1
|
2
|
4
|
3/4 |
0.56
|
13.8
|
25
|
40
|
3.2
|
6
|
10
|
1.6
|
4
|
4
|
1 |
0.75 |
16 |
32 |
40 |
4.2 |
8 |
10 |
2.1 |
4 |
6 |
1.5 |
1.12 |
20 |
40 |
50 |
6 |
10 |
16 |
3 |
6 |
10 |
2 |
1.49 |
24 |
50 |
63 |
6.8 |
16 |
20 |
3.4 |
6 |
10 |
3 |
2.24 |
34
|
63
|
82
|
9.6
|
20
|
25
|
4.8
|
8
|
16
|
5 |
3.73 |
56
|
100 |
150
|
15.2
|
32
|
40
|
7.6
|
16
|
20
|
7.5 |
5.60 |
80
|
160
|
200
|
22
|
40
|
63
|
11 |
20
|
32
|
10 |
7.46 |
100
|
200 |
250
|
28
|
50
|
80 |
14
|
25
|
40 |
15 |
11.2 |
131
|
250
|
350
|
42
|
80
|
125
|
21
|
40
|
63
|
20 |
14.9
|
|
|
|
54 |
100
|
150
|
27
|
50
|
82
|
25 |
18.7 |
|
|
|
68
|
125
|
175
|
34
|
63
|
100
|
30 |
22.4
|
|
|
|
80
|
160 |
200
|
40
|
80
|
100
|
40 |
29.8
|
|
|
|
104
|
200
|
300
|
52
|
100
|
150
|
50 |
37.3 |
|
|
|
130
|
250
|
300
|
65
|
125
|
175
|
LA TABLA ANTERIOR NOS PROPORCIONA LA CORRIENTE QUE CONSUME UN MOTOR EN LAS TENSIONES DE 115, 220 Y 440 VOLTS ASÍ COMO LA PROTECION QUE DEBE UTILIZAR YA SEA UTILIZANDO UN FUSIBLE O UN INTERRUPTOT TERMOMAGNETICO, LOS CUALES SE PUEDEN CALCULAR DE LA SIGUIENTE FORMA:
CORRIENTE PARA UN MOTOR MONOFASICO O 115 V:
IP= P/ E COS 0 N
DONDE EL SIGNIFICADO DE CADA UNA DE LAS LITERALES ES:
IP= CORRIENTE NOMINAL O A PLENA CARGA QUE CONSUME UN MOTOR (AMPERS)
P= POTENCIA QUE DESARROLLA UN MOTOR (WATTS O KILOWATTS)
E= TENSION A LA QUE SE CONECTA EL MOTOR (VOLTS)
COS 0= FACTOR DE POTENCIA
N= RENDIMIENTO DEL MOTOR
LA CORRIENTE PARA UN MOTOR TRIFASICO CONECTADO A 220 O 440 vOLTS
SE AFECTA EN EL DENOMINADOR POR LA RAIZ CUADRADA DE 3, LA CUAL REPRESENTAREMOS EN LA ECUACION POR /3
IP = P / /3 E COS 0 N
NOTA: EL VALOR DE LAS LITERALES EL EL MISMO
EJEMPLO 1:
DETERMINAR LA CORRIENTE QUE CONSUME UN MOTOR MONOFASICO EL CUAL ESTA CONECTADO A UNA FUENTE DE ALIMENTACION DE 115 VOLTS Y TIENE UNA POTENCIA DE 1/2 H.P. EL CUAL TIENE UN FACTOR DE POTENCIA DE 0.6 EN ATRASO Y UN RENDIMIENTO DE 55%.
DATOS
MOTOR MONOFASICO CALCULO DE LA CORRIENTE
IP= ?
E= 115 VOLTS IP = P / E COS 0 N
P= 1/2 H.P. = 370 WATTS
COS 0 = 0.6 IP = 370 / 115*0.6*0.55
N= 0.55
IP = 9.74 AMPERS
COMO PODEMOS OBSERVAR EL RESULTADO ES MUY SEMEJANTE AL DE LA TABLA ANTERIOR PARA UN MOTOR DE 1/2 H.P Y TENSION DE 115 VOLTS.
EJEMPLO 2.
CALCULAR LA CORRIENTE QUE CONSUME UN MOTOR TRIFASICO QUE SE CONECATA A UNA TENSION DE 220 VOLTS , EL CUAL TIENE LOS SIGUIENTES DATOS DE PLACA: POTENCIA 5 H.P. ; FACTOR DE POTENCIA 0.65 EN ATRASO Y RENDIMIENTO DE 50%
DATOS
MOTOR TRIFASICO CALCULO DE LA CORRIENTE
IP =?
E= 220 IP = P / /3 E COS 0 N
F.P.= 0.80
N= 0.80 IP = 3730 / 1.732*220*0.8*0.85
P= 3.73 KW = 5 H.P.
IP = 15.29 AMPERS
DEBEMOS COMPARAR EL RESULTADO CON EL DE LA TABLA Y PODEMOS OBSERVAR QUE ES MUY SEMEJANTE AL DE UN MOTOR TRIFASICO DE 5H.P. Y TENSION DE 220 VOLTS